Fire Alarm "Thermostate Based"

Fire alarm

An automatic fire alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. In general, a fire alarm system is either classified as automatic, manually activated, or both. Automatic fire alarm systems can be used to notify people to evacuate in the event of a fire or other emergency, to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke.

 

Design

After the fire protection goals are established - usually by referencing the minimum levels of protection mandated by the appropriate model building code, insurance agencies, and other authorities - the fire alarm designer undertakes to detail specific components, arrangements, and interfaces necessary to accomplish these goals. Equipment specifically manufactured for these purposes are selected and standardised installation
methods are anticipated during the design.        
                                                               (C.K.T. Diagram For Automatic Fire Alarm)  

Working

Fire alarm control panel: This component, the hub of the system, monitors inputs and system integrity, controls outputs and relays information. Primary Power supply: Commonly the non-switched 120 or 240 Volt Alternating Current source supplied from a commercial power utility. In non-residential applications, a branch circuit is dedicated to the fire alarm system and its constituents. "Dedicated branch circuits" should not be confused with "Individual branch circuits" which supply energy to a single appliance. Secondary (backup) Power supplies: This component, commonly consisting of sealed lead-acid storage batteries or other emergency sources including generators, is used to supply energy in the event of a primary power failure. Initiating Devices: This component acts as input to the fire alarm control unit and are either manually or automatically activated. Notification appliances: This component uses energy supplied from the fire alarm system or other stored energy source, to inform the proximate persons of the need to take action, usually to evacuate. Building Safety Interfaces: This interface allows the fire alarm system to control aspects of the built environment and to prepare the building for fire and to control the spread of smoke fumes and fire by influencing air movement, lighting, process control, human transport and exit.


Fire Alarm System 

Fire Alarm Guide is your ultimate source for information on fire alarm systems for your home and business with articles and advice that is focused on all of your life safety needs.  We offer resources for the leading brands of commercial fire alarm systems on the market with comprehensive information on the equipment, installation, maintenance and monitoring of your industrial or commercial fire alarm system.  Learn everything there is to know and more about commercial fire detection, fire suppression, fire protection, fire prevention and life safety systems.  Find a fire alarm manufacturer, fire alarm distributor, fire alarm supplier, fire alarm provider, fire alarm contractor, fire alarm dealer and fire alarm company.

Using martial 

Starter
When you turn on a fluorescent tube, the starter is a closed switch. The filaments at the ends of the tube are heated by electricity, and they create a cloud of electrons inside the tube. The fluorescent starter is a time-delay switch that opens after a second or two. When it opens, the voltage across the tube allows a stream of electrons to flow across the tube and ionise the mercury vapour. In this 'Model the stater is using for switching the main CKT, or to sense the change in Temperature (As a Thermostat)'.

Switch

In electronics, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another. The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts. Each set of contacts can be in one of two states: either 'closed' meaning the contacts are touching and electricity can flow between them, or 'open', meaning the contacts are separated and nonconducting.In this Model 'Switch is using for activation or deactivation of model'.

"Electric bell
systems consist of the bell, a battery which furnishes the, An electric bell is sounded by the striking of a clapper actuated by a Hammer" In this Model 'Bell is main indicator For warning of fair'.









Board and Wire

Board is a base of installation all  integral material it should be made of soft top with side cover of wooden stripe's  for the fire alarm we can go with any of the size like 8x12 or 12x18 and also paint or decorate it as per your own imagination. Wire is wising for transmitting power/ electricity we can use the gauge as per load of indicator's or attached resistance.

Actul Example of Working at Exhibition....!!